Monitoring of analog values
Full insight into the voltage trend
monitoring of the set limits
CML4055
Mobeye GM-Guard
The Mobeye CM-Guard TwinLog (CML4055) is a voltage monitor, ideal for use as a batteryguard. In an alarm situation, it sends notifications via push message, call, SMS or e-mail. It also logs the analog values and sends them to an online portal for visualisation as a graph, gauge or table.

Battery monitoring.
Complete and user friendly voltage monitor with alarm and log functions. For reliable monitoring of the analog values and sensors You can prevent damage by timely intervention.
Measurement of analog values
The inputs are suitable for measuring analog values between 0V and 48V, with peaks up to 64V. The alarm limits are adjustable in decimal precision.
The interval for logging the values and transfer to the portal are adjustable.
Alarm messages
In an emergency, the Mobeye CML4055 sends alerts via app (iOS/Android), phone call (voice message), text message and/or email. The message also includes the current readings. For push notifications, you can choose between an escalation plan or a group message. With the escalation plan, the recipient can acknowledge the push notification, meaning the other contacts will no longer receive the message. If none of the recipients acknowledge the push notification, a call will still be made. The number of contacts is unlimited.
External voltage vs battery powered
The Mobeye CML4055 can run on its internal batteries for a long time which makes it independent of an external power source. If an external power source is available, it is recommended to connect it. The availabiltity of the power supply is then monitored. it will also send power failure alarms. If there is outage, a notification follows. The batteries take over and the CML4055 will continue to monitor and send alarm messages. Once the power restores a notification will be sent. The batteries are included in the standard product. A country-specific mains adapter is available as accessory.
Alarm inputs, piezo siren and open collector output
The Mobeye CML4055 has two inputs. Both are suitable for analog measurement (AN) or for a normally open (NO) or normally closed (NC) contact. In the event of an alarm an audible alarm indication can sound by the internal piezo siren. In addition to this an (open collector) output is available to switch an external device.
Network and SIM card
The Mobeye SIM card provides the device with full functionality, including access to the Mobeye Portal and the app. With the Mobeye SIM card, communication takes place via the 4G network, with 2G as a fallback. It therefore supports the logging function. The voltage curve and status are displayed in the portal.
If you insert your own SIM card, the logging function and other portal functions will no longer be available. Alarm notifications will then be sent via text message and/or call to a maximum of 5 telephone numbers.
Product Information
Download available information. Still have a question, let us know!
Applications Mobeye CML4055
Battery monitoring
Car or boat battery monitoring
Analog sensors

insight and prevention
- Alarm via app, call, text and email
- Alarming at high or low limit
- Complete voltage trend in a graph
- Power failure monitoring (if connected to external voltage)
- Two AN/NO/NC alarm inputs
- Siren
- Full understanding of the device when connected to the Mobeye Portal
Cml4055
Mobeye CM-Guard-Twinlog
Summary of Features
Functions
- Voltage alarm
- Graphical representation of the values
power failure monitoring - Power failure monitoring
- 2x alarm input (AN/NO/NC)
Alarming
- To private contacts via an app, call, SMS and/or email, or to an emergency room (ARC)
Messages
- Power outage and power recovery
- Input alarm, (optional) alarm reset
- Battery low voltage, (missed) test message
Other settings
- Alarm limits between 0V and 48V
- Log interval 2 … 9999 minutes
- Transmission interval to portal 1 … 999 hours
- Delay time on input alarm and power failure alarm
- Alarm repetition frequency
- Inputs adjustable as AN, NO or NC
- Silent or audible siren
- Identification text, alarm texts
- Calibration value
- Automatic switch-on and switch-off times
Mobeye SIM card (option)
- Online activation
- Provides access to the Mobeye Portal and App
- Multi-provider, non-steering, flat-fee contract
Mobeye Portal and App
(with Mobeye SIM card)
- Alarm per push messages/SMS/call/email/ARC
- Push messages as group message or sequential
- Log values as graph, meter or table (and download)
- Status display
- Online programming
- Keep-alive monitoring
- Position display (Cell-ID)
Own SIM card (option)
- Alarm notifications via SMS text message and call to max. 5 contacts
Dimensions
- 94 x 94 x 28 mm
Power supply
- 2x CR123, or
- 12-24V DC + 2x CR123
Battery life
- 1 year (if battery-operated)
- 3 years (external power)
Communication module
- 4G + 2G Quadband
Contents
- CML4055
- 2x CR123 batteries
- Mobeye SIM card (optional use)
Accessoires
- Mains adapter, external antenna